Engineering Knowledge Cards.
Confidence HighUpdated 2026-09-25

Per-machine fuel accounting for construction equipment and identifying abnormal fuel consumption

Per-machine fuel is accounted by ledger back-calculation: actual consumption = opening tank fuel + current refills - closing tank fuel, converted with operating shifts/hours into four unit-consumption metrics (per shift, per hour, per m3, per tonne-km); compared against three baselines—quota shift energy, factory rating, own historical average: within +/-10% normal; above +15% yellow flag for investigation; above +30% red flag, halt and audit; supplemented by refueling logic checks, trend-jump monitoring, and fuel-level/GPS technical controls to identify anomalies.

Applicable Codes

  • T/SZZS 01 001-2021 建筑装饰碳排放计算标准
  • GB/T 51366-2019 建筑碳排放计算标准
  • JGJ/T 222-2011 建筑工程可持续性评价标准
  • TB/T 10814-2024 铁路工程施工机具台班费用定额

Topic Positioning

Accounting basis and anomaly identification for per-machine fuel consumption of fuel-driven construction equipment (excavators, rollers, loaders), for project equipment fuel management and cost control.

Core Conclusions

(1) The authoritative accounting basis is ledger back-calculation: actual consumption = opening tank fuel + current refills - closing tank fuel; the ledger records four elements—refuel time, fuel type, volume, machine ID—combined with operating shift/hour records to derive unit consumption. (2) Four unit-consumption metrics: per-shift fuel (L/shift, earthwork/pavement machines); per-hour fuel (L/h, continuous operation); per-m3 fuel (L/m3, output-based assessment); tonne-km fuel Fo = sum(Ki x Di) (haulage machines). (3) Three baselines: quota shift energy (planning/tendering basis, from shift-rate quotas or energy-standard appendices); factory rated consumption (new machine acceptance); own historical average (last 3-6 months, the most practical dynamic baseline during operation). (4) Alert thresholds: deviation within +/-10% is normal fluctuation; above +15% yellow flag—check leaks, idling, private use, operating habits; above +30% red flag—halt and audit (fuel theft/resale/serious faults). (5) Four anomaly checks: compare against baselines; check refueling logic contradictions (single refuels exceeding tank capacity, late-night refuels, refuel frequency mismatched with operation); check trend jumps (normal aging climbs +1%-2% per month; a +20% month-over-month jump is usually abnormal); technical backstops (fuel-level sensors/GPS, one card per vehicle e-fuel cards, monthly count error >2% triggers investigation).

Applicable Boundaries

Applies to fuel-powered earthwork/pavement/haulage machines; electric or externally powered machines excluded. Quota shift energy values vary by quota edition—verify against the quota actually adopted; do not mix across quotas. Machines over 5 years old running 10%-15% above quota is normal—adjust baselines by machine age; the +/-10%/+15%/+30% thresholds are management experience values that enterprises may customize.

Further Reading

(1) Quota shift energy baselines: T/SZZS 01 001-2021 Standard for Carbon Emission Calculation of Building Decoration, Appendix C Table C.0.1 (e.g., crawler dozer 75kW ~= 56.5kg, 1m3 excavator ~= 63kg diesel per shift). (2) Construction-stage energy estimation: GB/T 51366-2019 Standard for Building Carbon Emission Calculation, Article 5.2.4, energy = sum(work quantity x unit shift consumption x shift energy use), with complete earthwork/rebar/concrete examples. (3) Haulage machine fuel: JGJ/T 222-2011 Evaluation Standard for Sustainability of Building Works, Article 5.2.5. (4) Shift-rate cost composition and energy basis: TB/T 10814-2024 Railway Equipment Shift Rate Quota, Chapter 1 general provisions.

Keywords

  • 机械油耗
  • 单机油耗
  • 燃油消耗
  • 油耗核算
  • 台账倒算法
  • 台班能耗
  • 油耗异常