Height limits for floor-type coupler steel-tube scaffolds: GB/T 50484-2019 Clause 6.1.10 (single-row banned above 24m, staged unloading above 50m) vs JGJ 130-2011 Clause 6.1.2
Per GB/T 50484-2019 Clause 6.1.10: floor-type coupler steel-tube scaffolds over 24m shall not use single-row scaffolds; double-row floor-type coupler scaffolds over 50m should adopt staged unloading. JGJ 130-2011 Clause 6.1.2: single-row scaffolds shall not exceed 24m; double-row preferably not over 50m; above 50m use staged erection, twin-tube standards (twin-tube over the upper 2/3), staged unloading, etc., with dedicated design and demonstration.
Applicable Codes
- GB/T 50484-2019 · Standard for Construction Safety Technology of Petrochemical Engineering Projects 第 6.1.10 条
- JGJ 130-2011 · Technical Code for Safety of Steel Tubular Scaffold with Couplers in Building Construction 第 6.1.2 条
- GB 51210-2016 · Unified Standard for Safety Technology of Scaffolding in Building Construction (配套参照)
Topic Positioning
Two control lines for floor-type coupler steel-tube scaffold height: in petrochemical construction, GB/T 50484-2019 Clause 6.1.10 (single-row banned over 24m; staged unloading over 50m), compared with the general industry standard JGJ 130-2011 Clause 6.1.2 - for direct citation in special construction plans, site safety checks, and compliance judgment.
Core Conclusions
I. GB/T 50484-2019 Clause 6.1.10 (Chapter 6 "scaffold operations"), original: "For floor-type coupler steel-tube scaffolds over 24m in height, single-row scaffolds are prohibited; double-row floor-type coupler steel-tube scaffolds over 50m should adopt staged unloading measures." Height control lines:
| Height | Control |
|---|---|
| <= 24m | single- or double-row both allowed |
| 24m < H <= 50m | single-row prohibited; use double-row |
| > 50m | double-row should adopt staged unloading |
II. JGJ 130-2011 Clause 6.1.2 (general industry), original: "Single-row scaffolds shall not exceed 24m; double-row scaffolds preferably not exceed 50m; above 50m, staged erection measures shall be adopted." Commentary rationale for the 50m preference: (1) decades of domestic practice show single-tube floor scaffolds are generally below 50m; above that, twin-tube standards, staged unloading, and staged erection are used prudently with proven methods; (2) economics - above 50m tube/coupler turnover drops and foundation treatment costs rise; (3) foreign limits: US 50m, Germany 60m, Japan 45m. Scaffolds over 50m using twin-tube standards (twin over upper 2/3) or staged unloading require dedicated design and demonstration per actual conditions; stability of the single standard above the twin-tube transition is checked by JGJ 130-2011 formulas (5.2.6-1)/(5.2.6-2), and the twin-tube bottom also requires a stability check.
Applicable Boundaries
- Clause 6.1.10 applies to scaffolds in petrochemical construction; building and other sectors follow JGJ 130-2011.
- In the petrochemical standard, 24m is a hard ban on single-row; 50m corresponds to "should adopt staged unloading" - not absolute but a safety requirement; ultra-high double-row scaffolds (>50m) on petrochemical projects shall define staged unloading in the approved special plan.
- In JGJ 130-2011, 50m is "preferably not exceed"; beyond it use staged erection/unloading/twin-tube standards with dedicated design - never simply extend.
- Local standards may be stricter (e.g., tighter single-row limits) - follow the project's local rules.
- Covers height limits only; coupler quality (no cracked, deformed, or thread-stripped couplers), bracing details, and acceptance checks are separate clauses to be applied together.
Further Reading
- Petrochemical: GB/T 50484-2019 Chapter 6, Clause 6.1.10.
- Industry: JGJ 130-2011 Clause 6.1.2 and commentary (50m rationale, twin-tube standards, staged unloading, formulas 5.2.6-1/2).
- Detail support: GB 51210-2016 Clause 8.2.3 vertical bracing (tiered at 24m) and Chapter 10 quality control.
- Other chapters of the same standard: hot work (Ch. 3), temporary power (Ch. 4) - see cited cards.
Keywords
- 落地脚手架
- 搭设高度
- 扣件式钢管脚手架
- 单排脚手架
- 双排脚手架
- 分段卸荷
- GB/T 50484
- JGJ 130