"Lintel" treatment over door/window openings in light-gauge steel stud partitions: head bracing is mandatory; a load-bearing lintel is not feasible
The "lintel" above openings in light-gauge steel stud partitions is in fact head bracing (constructional reinforcement) and is mandatory: the head horizontal runner over the jamb opens upward; jack runners flanking the opening open away from it; studs above the head are inserted and densified; fixing screws at <= 300 mm spacing with >= 2 screws per point; openings > 1800 mm wide or heavier doors/windows require additional reinforcement, and where door/window weight >= 25 kg rectangular steel tubes or channels are used at the opening edges. A load-bearing lintel is not feasible — the partition is non-load-bearing, and structural loads are carried by the main structure.
Applicable Codes
- DBJ52/T 118-2024
- DB62/T 3026-2018
- DBJ50/T 337-2019
- DB11/T 1832.22-2023
- DB11/T 1832.10-2022
- JGJ/T 157-2014
- DB11/T 1668-2019
Topic Positioning
Whether a "lintel" can be made over door and window openings in light-gauge steel stud (gypsum-board and composite-faced) partitions, and the standard reinforcement construction and grading requirements above and beside openings. Applies to design and construction of light-steel stud partitions, and distinguishes the lintel-board system of lightweight panel partitions.
Core Conclusions
Two types of "lintel" must be distinguished: (1) head bracing (constructional lintel) — feasible and mandatory: the head over the opening is made of horizontal runner with its opening upward; jack runners are added on both sides of the opening with openings facing away from it; vertical studs are inserted between the head and the top runner and densified (spacing smaller than that of the other studs in the wall body); additional runners are provided at opening sides and corners per design; reinforcing runners and the head module are connected with self-drilling screws at fixing spacing preferably not greater than 300 mm and not fewer than 2 per point. (2) Load-bearing lintel — not feasible: light-steel stud partitions are non-load-bearing walls; structural loads must be carried by the main structure, and transferring them to the partition is strictly forbidden. Reinforcement grading: openings <= 600 mm wide with door/window weight <= 25 kg — timber inserts inside the opening-edge runners suffice; door/window weight >= 25 kg (steel doors, fire doors, heavy glass doors) — rectangular steel tubes or channels at the opening edges; heavy doors/windows or openings > 1800 mm wide require further reinforcement (larger runner sections, denser spacing, added steel beams).
Applicable Boundaries
Applies only to light-gauge steel stud partition systems. Panel partitions (JGJ/T 157-2014): where the wall above the door/window jamb panel exceeds 600 mm in height or the opening exceeds 1.5 m in width, a reinforced lintel board must be used with >= 100 mm bearing at both ends — the idea may be referenced but the practice differs; do not mix. Heavy-door openings must load the steel door-frame sections, with the light-steel studs serving only as infill. Where a frame beam happens to sit above an opening, the studs simply bear against the beam soffit — no lintel is needed. This card does not cover load-bearing conversion or structural calculation of partitions.
Further Reading
Main bases: DBJ52/T 118-2024 Clause 6.3.12; DB62/T 3026-2018 Clause 8.4.6 (also sound-insulation door/window requirements); DBJ50/T 337-2019 Clause 5.4.12 (600 mm/25 kg grading); DB11/T 1832.22-2023 Clause 3.4.4; DB11/T 1832.10-2022 Clause 10.5.3; JGJ/T 157-2014 Clause 4.3.11 (panel system); DB11/T 1668-2019 Clause 5.3.4 (sequence of erecting the two side studs first).
Keywords
- 轻钢龙骨隔墙
- 过梁
- 门头横撑
- 门窗洞口加固
- 附加龙骨
- 竖龙骨加密
- 轻质隔墙洞口
- 条板隔墙过梁板