Classifying and measuring slope treatment works by protection type: plant protection by slope area, masonry protection by masonry volume, anchoring and facing listed apart (anchor length / mass + facing area), SNS flexible nets by laid area with anchors and posts separate

Slope treatment pricing first fixes the sector system (railway / highway / municipal) and the protection type, then itemises on the measurement line: (1) plant protection (grass seeding, hydro-seeding, geotextile mats, planting bags) by laid slope area; (2) masonry protection (mortared rubble slope protection, skeleton (rib) protection, protection walls) by solid masonry volume, rendering and pointing extra by area; (3) anchoring + facing (anchor-mesh hydro-seeding, shot-seed-mix, anchor-mesh shotcrete) split with anchors by design length / mass and facings by area / volume; (4) SNS flexible protection nets by design laid area, with anchors and post foundations / posts listed separately. What the work content already includes (meshing, scaffolds, energy dissipators etc.) is never listed again.

Applicable Codes

  • TB/T 10822-2024 铁路工程预算定额 Vol. 1 路基工程 Ch. 4 平(坡)面防护
  • TB/T 10822-2024 Vol. 1 Ch. 5 护坡及冲刷防护
  • TB/T 10822-2024 Vol. 1 册说明 第二部分 Ch. 4、Ch. 5分章说明
  • JTG/T 3832-2018 公路工程预算定额 补充子目 1-5-8 边坡柔性防护

Positioning

The classification framework and per-type measurement lines for pricing slope treatment works (subgrade slope protection), across the railway, highway and municipal quota systems - answering the generic question 'what unit and how many items per slope method'.

Core conclusions

1. Two steps to fix the path

Step 1, fix the sector: slope treatment sits in different chapters of railway (TB/T 10822-2024 etc.), highway (JTG/T 3832-2018 system) and municipal / local consumption quotas - different item division, units and charging; no cross-borrowing; only on gaps may similar processes be referenced or a supplementary unit-rate build-up schedule compiled. Step 2, fix the protection type into one of four classes and itemise on its measurement line.

2. The four measurement lines

(1) Plant protection (seeding, hydro-seeding, geotextile mats, planting / eco-bags) - by laid slope area

  • Railway chapter 4 section 2: LY-310 seeding, LY-311~316 hydro-seeding (100m2, banded by embankment / cutting x normal / arid / cold); rules: 'plant protection is measured by design quantity', 'slope geotextile mats are measured by design laid area, seeding already included'.
  • Highway: grassed slope protection (manual, meshed, hydro-seeded, seed-mix, soil-spray) by the slope area laid; hydro-seeding items already cover binder, water-retainer, fertiliser and film - no conversion; only seed consumption adjusts to design.
  • Municipal / local: hydro-seeding by the outer developed area from the drawings, banded 30~45, 45~60, over 60 degrees (100m2).
  • Eco / planting bags: eco-bags by slope area; planting bags flat by area, stacked by volume.

(2) Masonry protection (mortared rubble slopes, skeleton protection, walls, precast blocks) - by solid masonry volume

  • Railway chapter 4: LY-394~397 mortared rubble slopes (10m3, height up to 8m / 16m x M7.5 / M10), rendering LY-398 and pointing LY-399 extra per 100m2; skeleton protection LY-403~407 (10m3, by height x mortared rubble / mortared concrete edging / cast-in-place concrete), grassing inside the skeleton stacked by area.
  • Railway chapter 5 rules: 'full-slope protection and walls compute foundation excavation only below the original ground (subgrade) line; skeleton protection adds the trench excavation on the slope'; 'masonry is measured by design outer dimensions in volume'; 'small precast members by design outer volume, hollow concrete blocks by solid volume'.

(3) Anchoring + facing (anchor-mesh hydro-seeding, seed-mix spraying, anchor-mesh shotcrete, soil-nail walls) - anchors and facing apart

  • Railway: seed-mix LY-317 anchors (t) + LY-318 at 10cm (100m2) with LY-319 per +/-1cm; shotcrete route LY-305 mortar anchors (100m) + LY-307 steel mesh (t) + LY-306 shotcrete (10m3).
  • Rules: 'anchors are measured by design length'; 'rebar mass = design length x theoretical unit mass; laps, welding wire, binding wire and spacers never enter the quantity'.
  • Meshing depends on work content: the seed-mix thickness item already includes 'hanging wire mesh' - no separate listing; the shotcrete route lists steel mesh separately. Soil-nail items exclude mesh and shotcrete - charge when needed.

(4) SNS flexible nets (active / passive) - nets by design laid area, anchors and posts separate

  • Railway chapter 4 section 4: active = wire-rope anchors LY-371 (100m) + net installation LY-372 (100m2); passive = post foundations LY-373 (10m3) + rebar anchors LY-374 (100m) + net installation LY-375 (100m2). 'High-strength metal nets are measured by design laid area'; volume note: 'active and passive net items exclude scaffold erection and removal - charge per design quantity under the relevant quota'.
  • Highway item 1-5-8 flexible slope protection: active / passive nets per 100m2, anchors per t, posts per 100m2 - separate items, anchors never merged into nets.

3. Three error guards

  1. What the work content includes is never listed again (meshing, support ropes, dissipators, toe anchors, scaffolds).
  2. When anchors, nets and substrates measure separately, each takes its design quantity - never fold anchors into a per-area lump.
  3. Excluded content is charged per the quota notes (nets' scaffolds, masonry foundation excavation and skeleton trenches, skeleton grassing) - omitting them is omission.

Applicable boundaries

  • A generic path for itemisation and measurement, replacing neither item contents nor base prices; price from the executing volume of the sector and the compilation-period prices.
  • No cross-borrowing between railway, highway and municipal systems; on true gaps, 'reference a similar process -> compile a supplementary schedule for approval'.
  • Banding conditions (height, slope angle, climate zone, embankment / cutting) must be fixed first or the band will be wrong; skeleton trenches and net scaffolds are frequent omissions - check the chapter notes.
  • Soil-nail walls and anchor frame beams belong to the retaining-structure chapters, not to this chapter's slope-face lines.

Further reading

Railway: TB/T 10822-2024 Volume 1, chapter 4 (shotcrete LY-305~307; green protection; high-strength flexible nets) and chapter 5 (slope masonry LY-394~399, skeletons LY-403~407) with volume notes; Highway: JTG/T 3832-2018 with supplement 1-5-8 flexible slope protection and greening chapter rules; Municipal: provincial slope-greening chapters (e.g. Shaanxi 2024 draft 6-1~6-4).