Floor quantity calculation rules: layered calibers and deduction/merge rules for cushion courses, surface courses, skirting, stairs, and steps
Floors are calculated by structural layer: cushion courses by net area between main walls x design thickness in m3; monolithic surface courses and leveling courses by net area between main walls in sqm (door openings not added); tiled surface courses by the laid area (openings merged); skirting by linear meters; stairs and steps by horizontal projected area (stair wells <= 500 mm not deducted; without landing beams, measured to the edge of the top tread plus 300 mm). BOQ items are listed per the tables of GB/T 50854-2024 Appendix L.
Applicable Codes
- GB/T 50854-2024 房屋建筑与装饰工程工程量计算标准 App. L
- TB/T 10831-2024 铁路工程预算定额 Vol. 10 房屋工程
- SJG 111.2-2022 城市地下综合管廊工程消耗量标准 Vol. 2
Topic Positioning
Floor quantities are calculated by structural layer: cushion courses, monolithic surface courses, tiled surface courses, skirting, stairs and steps — each layer has a different caliber and they must not be mixed.
Core Conclusions
Cushion courses by net area between main walls x design thickness in m3; monolithic surface courses and leveling courses by net area between main walls in sqm — both deduct structures and equipment foundations protruding from the floor, do not deduct columns, pilasters, partition walls, or holes <= 0.3 sqm, and do not add door openings and void rings. Tiled surface courses by the laid (actually paved) area, deducting positions without a surface course and merging openings — the opposite of monolithic courses. Skirting by linear meters (mortar-type: openings not deducted; tile-type: door openings deducted with side walls added). Stairs by horizontal projected area including treads, landings, and stair wells <= 500 mm; where connected to floors, measured to the inner side of the landing beam; without a landing beam, to the tread edge plus 300 mm; steps likewise plus 300 mm. BOQ items are listed per the tables of GB/T 50854-2024 Appendix L (011101/011105/011106).
Applicable Boundaries
Applies to floor quantity takeoff for building works; quota calibers vary by region (Jiangsu/Shaanxi quotas, SJG 111.2-2022, TB/T 10831-2024) — the current local quota governs; road structural layers, walls, and ceilings are not covered.
Further Reading
GB/T 50854-2024 Appendix L (L.1.1/L.5.1/L.6.1/L.10.3/L.10.8); quota calibers: TB/T 10831-2024 Volume 10, SJG 111.2-2022 Volume 2, and the current consumption quotas of the provinces.
Keywords
- 楼地面
- quantity take-off (measurement)
- 垫层
- 整体面层
- tile and stone finishes
- 踢脚线
- 楼梯面层
- 台阶
- 主墙间净面积
- 水平投影面积