Applicability relationship between comprehensive scaffolding and individual scaffolding and their quantity calculation rules (railway buildings quota TB/T 10831-2024)

Comprehensive scaffolding and individually priced scaffolds must not be double-counted on the same project: only items unsuitable for comprehensive scaffolding are executed under the corresponding individually priced scaffold items. Comprehensive scaffolding is calculated by gross floor area (GFA); exterior scaffolding by exterior wall face length × height (no deduction for door/window openings); birdcage (full-area) scaffold by clear indoor area split into a basic layer and additional layers; isolated columns and cast-in-place beams apply the double-row exterior scaffolding item × factor 0.30.

Applicable Codes

  • TB/T 10831-2024 · Budget Quota of Railway Engineering (Volume 10: Housing Works) 册说明四、五、六
  • TB/T 10831-2024 Ch. 1土建工程第四节 脚手架工程(FY-415~FY-442)
  • 湖南 2025 版《房屋建筑与装饰工程消耗量标准》第十八章 脚手架工程
  • 陕西《新编消耗量定额》(征求意见稿)脚手架工程量计算规则
  • 江苏省 2026 版《建筑与装饰工程消耗量标准》脚手架章

Topic Positioning

This card covers the core rules of the scaffolding works of the railway buildings quota (TB/T 10831-2024 Vol. 10): the applicability relationship between comprehensive and individually priced scaffolds, and the quantity take-off (measurement) rules for each scaffolding type, for budget preparation, measurement and pricing, and compliance checking.

Core Conclusions

Comprehensive scaffolding and individually priced scaffolds must not be double-counted on the same project: only items unsuitable for comprehensive scaffolding are executed under the corresponding individually priced scaffold items. Comprehensive scaffolding is calculated by gross floor area (GFA), with eaves height taken from the design outdoor ground to the drip line of the eaves; stair rooms, lift rooms, water tank rooms, and skylights projecting above the roof are excluded. Exterior scaffolding is calculated by area as the exterior wall face length (including pilasters and attached shafts) × exterior wall height; where a parapet exists, measured to the parapet top; no deduction for door/window openings; where the same building has different heights, calculated separately. Birdcage (full-area) scaffold is calculated by clear indoor area: heights 3.60–5.20 m count as the basic layer, above 5.20 m each additional 1.20 m counts one additional layer, and remainders under 0.60 m count as one additional layer × factor 0.50. Interior scaffolding and interior wall finishing scaffolding are calculated by the vertical projected area of the wall face, without deducting door/window openings. Isolated columns: structural perimeter plus 3.60 m × height, applying the double-row exterior scaffolding item × factor 0.30; cast-in-place concrete beams: height from beam top to ground (floor) × clear beam span, likewise applying double-row exterior scaffolding × factor 0.30. Exterior scaffolding already includes ramps, loading platforms, and guard rails; where the story height exceeds 3.60 m and the ceiling requires plastering, painting, or suspended ceilings, birdcage (full-area) scaffold may be added, but wall finishing scaffolding is no longer calculated for that part.

Applicable Boundaries

Applies to the quota basis of railway building works (TB/T 10831-2024 Vol. 10). Local quotas (e.g., the Beijing 2021 building and decoration consumption standard) follow the same "no double counting" principle, but item divisions and factors (e.g., birdcage (full-area) scaffold height bands) may differ slightly — the current local quota notes govern. Where full steel-pipe staging quotas are used for over-height/over-weight beam-slab formwork, the over-height concrete placing surcharge is not counted again.

Further Reading

See TB/T 10831-2024, Railway Budget Quota Vol. 10 Buildings, Section 4 "Scaffolding Works", items "IV. Comprehensive scaffolding", "V. Individually priced scaffolds", "VI. Quantity take-off (measurement) rules"; the volume notes additionally govern interior wall finishing, addition of birdcage (full-area) scaffold, parapets over 1.20 m using interior scaffolding, and factors for members placed beyond 3.60 m indoors.